Specialist EPS MultiBoost water pressure pump repairs, servicing, fault diagnosis and replacement throughout Dublin.
Is your EPS MultiBoost pump running continuously, losing water pressure, switching on and off repeatedly, making excessive noise or failing to start?
At Boosterpumps.ie, we specialise in diagnosing and repairing domestic water pressure boosting systems, including EPS MultiBoost tank and pump installations.
Based in Terenure, Dublin 6, we provide mobile water pump repair and replacement services throughout Dublin.
Whether the problem is caused by a faulty pump, an electronic controller, a leaking non-return valve or an issue with your water storage tank, we aim to identify the underlying fault before recommending repair or replacement.
For EPS MultiBoost pump advice, call 083 206 3931.
The EPS MultiBoost is a packaged water pressure boosting system manufactured by EPS Group in Ireland.
It combines a cold-water storage tank with a pump and automatic control system to provide increased water pressure and flow throughout a property.
The incoming supply fills the storage tank, and the pump delivers water to showers, taps and other connected outlets when required.
Unlike a standalone inline booster pump, the EPS MultiBoost stores water before pumping it, making it suitable for installations where the incoming supply has insufficient pressure or flow.
Depending on the model, the system may include:
The precise components depend on the age and specification of the unit.
The EPS MultiBoost range includes several tank configurations and control options.
Designed for installations where available height may be restricted, including houses and apartments.
A space-saving tank and pump arrangement commonly suited to utility rooms, garages or under-stairs locations.
A range of larger water storage and boosting units for properties with greater water demand.
A compact under-stairs boosting system with selected single-pump and twin-pump configurations.
These use automatic pump controllers to start and stop the pump according to water demand.
These incorporate electronic speed regulation designed to maintain a more consistent delivery pressure as household water demand changes.
If you are unsure which EPS MultiBoost model is installed in your property, send us a photograph of the tank, pump controller and identification label.
One of the most common symptoms of a water booster system fault is a pump that continues running after all taps and showers have been turned off.
Possible causes include:
Continuous operation can increase energy consumption and place unnecessary strain on the pump.
A MultiBoost pump that will not switch off does not automatically need replacing.
The connected plumbing system, controller and pump should be investigated before deciding on repair or replacement.
If your MultiBoost previously delivered good shower and tap pressure but is now struggling, there may be a problem with either the water supply or pump performance.
Possible causes include:
The tank water level and available pump flow should be checked before increasing pressure settings or replacing equipment.
Frequent pump starting and stopping, sometimes called short cycling, may indicate pressure loss or a controller problem.
Possible causes include:
Some EPS MultiBoost fixed-speed controllers include an integrated pressure vessel designed to reduce unnecessary cycling from minor pressure fluctuations.
Where a vessel is fitted, its condition and pre-charge may need checking in accordance with the relevant manufacturer's instructions.
Repeated cycling should be investigated before it causes additional wear.
If the pump fails to operate when a tap is opened, possible causes include:
EPS MultiBoost systems incorporate pump protection features on relevant models, which may stop operation when an inadequate water supply is detected.
The cause of the shutdown should be identified before attempting repeated restarts.
An EPS MultiBoost system should operate without sudden grinding, rattling, harsh vibration or unusually loud mechanical noises.
Although some operating sound is normal, an increase in noise can be an early indication of a developing problem.
Possible causes include:
Worn pump bearings
A worn motor bearing may cause rumbling, grinding or whining while the pump is operating.
Damaged impellers
A worn or damaged impeller may affect water pressure and create abnormal vibration or mechanical noise.
Cavitation or restricted water supply
A rattling or gravel-like sound may indicate that the pump is not receiving adequate water.
Low water level
An inadequate water level can affect pump performance and cause protective shutdowns or noisy operation.
Vibration through pipework
Poorly supported pipework or rigid connections may transfer vibration to floors, walls and surrounding structures.
Loose components
Mounting issues or unsecured fittings may cause unnecessary rattling during operation.
In many cases, excessive noise can be investigated without immediately replacing the complete tank and pump system.
Depending on the cause, repairs may involve correcting water supply restrictions, adjusting pipework, replacing accessible components or assessing the submerged pump assembly.
If the pump develops sudden severe noise, overheats or loses water delivery, switch it off safely and arrange professional inspection.
The MultiBoost range includes dry-running protection on relevant controllers to help prevent damage when the stored water supply is inadequate.
If your system repeatedly shuts down, possible causes include:
Some systems automatically attempt to restart after a delay.
Repeated dry-running shutdowns should not be ignored. The water supply and controller should be checked to establish why the system is stopping.
If the tank is not filling correctly, the pump may be starved of water even when the electrical and pumping components are working.
Possible causes include:
We can investigate the supply arrangement and determine whether the problem is associated with the tank filling system rather than the pump itself.
If water is escaping from the tank, overflowing continuously or appearing around the installation, it is important to identify the source.
Possible causes include:
An overflowing tank is not necessarily a pump failure.
Where an EPS MultiBoost is installed in an attic or another location above occupied rooms, leaks and overflow problems need particular attention to avoid property damage.
Never block or cap a tank overflow to stop visible water discharge.
The automatic controller is an important part of the EPS MultiBoost system.
Different models may use different controllers, including:
Automatically starts and stops the pump according to pressure and flow conditions.
Possible faults include failure to start, failure to stop or protective shutdowns.
An automatic controller with adjustable operating settings on applicable versions.
Some versions incorporate a small pressure vessel to help reduce frequent cycling.
Possible faults include:
A variable-speed controller designed to adjust pump output as demand changes.
Possible symptoms include:
The correct repair depends on the specific controller and the fault identified.
EPS MultiBoost systems are available with different control arrangements.
Fixed-speed systems normally operate the pump at its designed speed when water demand requires it. Delivered pressure can vary as the amount of water being used changes.
Variable-speed systems adjust motor speed to help maintain a more consistent pressure across different levels of demand.
When assessing a fault, it is important to establish which system is installed.
For example, a gradual reduction in pressure under heavy demand on a fixed-speed unit does not necessarily indicate a malfunction. Conversely, significant pressure instability on a variable-speed system may justify checking the pressure controls, water supply and pump performance.
We can assess the existing installation and explain whether the problem is normal system behaviour or a repairable fault.
Yes, in some circumstances the faulty component can be repaired or replaced without replacing the entire MultiBoost system.
Depending on the fault and the availability of compatible components, possible remedial work may include:
If the storage tank remains in good condition, replacing the entire system may not always be necessary.
However, where the tank is damaged, parts are unavailable or several major components have failed, a complete replacement may be more economical.
At Boosterpumps.ie, we aim to establish the most practical repair solution before recommending a new installation.
Where repair is no longer practical, we can assess the system and advise on a suitable replacement.
Factors to consider include:
We can discuss whether replacing an individual pump, fitting a suitable alternative or upgrading the complete boosting system would be the better option.
Any replacement needs to be correctly specified for the existing plumbing system and applicable installation requirements.
Boosterpumps.ie specialises in domestic water boosting systems, pump repairs, servicing and replacements throughout Dublin.
We understand the importance of diagnosing the whole installation rather than assuming every loss of water pressure is caused by the pump.
Our services include:
We are based in Terenure, Dublin 6, and provide services throughout Dublin.
Possible causes include leaking pipework, faulty non-return valves, incorrect controller operation or an inability to maintain water pressure. A proper diagnosis is needed to establish the cause.
Repeated cycling may result from pressure loss, small plumbing leaks, a faulty controller, a non-return valve problem or a defective pressure vessel on systems where one is fitted.
Possible causes include damaged impellers, worn bearings, poor water supply, vibration through pipework or mechanical wear within the pump.
Potentially. If the tank and other components remain suitable, a compatible replacement pump may be an option. The exact model, hydraulic performance, control arrangement and installation requirements must first be assessed.
Some versions, particularly those using certain Presflo Multi controllers, include an integrated pressure or accumulator vessel. The equipment fitted varies by model and age.
EPS identifies applications with suitable pressurised hot-water systems, including combination boilers. However, compatibility depends on the complete property installation and should be verified before replacing or modifying the system.
Boosterpumps.ie provides water pump fault diagnosis, repair assessments and replacement services throughout Dublin from Terenure, Dublin 6.
If your EPS MultiBoost system has stopped working, is losing pressure or has become noisy, contact us before deciding to replace it.
For initial advice, please provide:
Call 083 206 3931
Email info@boosterpumps.ie
Boosterpumps.ie — Water Pump Repair, Servicing and Replacement Specialists, Dublin.